Set the tray to eject output paper that does not satisfy the standard.
This function allows you to combine Purge tray of Relay Unit RU-702 with the optional Secondary (sub) tray mounted later, and also select the same tray as a job.
Category | Adjustment / Maintenance | ||
Location | Machine | Touch Panel | |
Printer driver | - | ||
Application | - | ||
Required options | All the following optional devices are required. Intelligent Quality Optimizer IQ-501 Auto Inspection Unit UK-301 Relay Unit RU-702 Video Interface Kit VI-514 Video Interface Kit VI-515 | ||
Required items | - | ||
Setting items | -[Same as the Job] | Ejects paper to the same output tray as a job when output paper does not satisfy the standard. | |
[Purge Tray] | Ejects paper to Purge tray when output paper does not satisfy the standard. | ||
[RU702 Only] | Ejects paper only to the Purge tray of Relay Unit RU-702 when output paper does not satisfy the standard. This setting is available when [Purge Tray] is selected. | ||
[RU702 + Sub Tray] | Ejects paper to the Purge tray of Relay Unit RU-702 and Secondary (sub) tray of another unit when output paper does not satisfy the standard. This setting is available when [Purge Tray] is selected. | ||
Remarks | -: Default If the available Secondary (sub) tray is not provided in Relay Unit RU-702 or later, [RU702 + Sub Tray] becomes inactive. | ||
Reference | - | ||
Screen access | Touch panel - Utility/Counter - [User Setting] - [Common Setting] - [Output Tray for Out of Range] |