Adjust the development AC bias for yellow, magenta, cyan, and black individually.
You can set whether to prioritize prevention of image noise and white spot or enhancement of development capability.
Category | Adjustment / Maintenance | ||
Location | Machine | Control Panel | |
Printer driver | - | ||
Application | - | ||
Required options | - | ||
Required items | - | ||
Setting items | [Y] | Select the color to adjust. | |
[M] | |||
[C] | |||
[K] | |||
[Set] | Sets the numeric value entered using the on-screen keypad to [Current Data]. Range: -5 to +5 | ||
[Default] | Returns [Current Data] to default. Default: 0 | ||
Keypad | Used to enter numeric values. | ||
[+ / -] | Sets the plus or minus of the numeric value. | ||
[Clear] | Returns the entered numeric value to "0". | ||
Remarks | - | ||
Reference | - | ||
Screen access | Control panel - Utility/Counter - [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Process Adjustment] - [Develop AC Bias Fine Adj.] |
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
Adjustment range: (Prevention of image noise and white spot) - 5 to +5 (Enhancement of development capability)